KNX 커버(KNX Cover)


이 통합구성요소를 사용하려면 knx 연동을 올바르게 설정해야합니다. KNX Integration을 참조하십시오.

knx 커버(Cover) 플랫폼은 KNX 커버에 대한 인터페이스로 사용됩니다.

설치에서 KNX 커버를 사용하려면 configuration.yaml 파일에 다음을 추가하십시오.

# Example configuration.yaml entry
cover:
  - platform: knx
    name: "Kitchen.Shutter"
    move_long_address: '3/0/0'
    move_short_address: '3/0/1'
    position_address: '3/0/3'
    position_state_address: '3/0/2'
    travelling_time_down: 51
    travelling_time_up: 61

Configuration Variables

name

(string)(Optional)

A name for this device used within Home Assistant.

Default value:

KNX Cover

move_long_address

(string)(Optional)

KNX group address for moving the cover full up or down.

move_short_address

(string)(Optional)

KNX group address for moving the cover short time up or down. If the KNX device has a stop group address you can use that here.

position_address

(string)(Optional)

KNX group address for moving the cover to the dedicated position.

position_state_address

(string)(Optional)

Separate KNX group address for requesting the current position of the cover.

angle_address

(string)(Optional)

KNX group address for moving the cover to the dedicated angle.

angle_state_address

(string)(Optional)

Separate KNX group address for requesting the current angle of cover.

travelling_time_down

(integer)(Optional)

Time cover needs to travel down in seconds. Needed to calculate the intermediate positions of cover while traveling.

Default value:

25

travelling_time_up

(integer)(Optional)

Time cover needs to travel up in seconds. Needed to calculate the intermediate positions of cover while traveling.

Default value:

25

invert_position

(boolean)(Optional)

Set this to true if your actuator report fully closed as 100%.

Default value:

false

invert_angle

(boolean)(Optional)

Set this to true if your actuator reports tilt fully closed as 100%.

Default value:

false