통합스위치솔루션(Digital Loggers)


digitalloggers 스위치 플랫폼을 사용하면 Digital Loggers 스위치의 상태를 제어할 수 있습니다.

설정

설치시 digitalloggers 스위치를 사용하려면 configuration.yaml 파일에 다음을 추가하십시오.

# Example configuration.yaml entry
switch:
  - platform: digitalloggers
    host: 192.168.1.43

Configuration Variables

host

(string)(Required)

The IP address or FQDN of your DIN III relay, e.g., 192.168.1.32 or myrelay.example.com.

name

(string)(Optional)

The name to use when controlling this relay.

Default value:

DINRelay

username

(string)(Optional)

Username for controlling this relay.

Default value:

admin

password

(string)(Optional)

Password for controlling this relay.

Default value:

admin

timeout

(integer)(Optional)

Override the timeout in seconds if you need to, valid range is 1 to 600.

Default value:

20

cycletime

(integer)(Optional)

This is the delay enforced by the library when you send multiple commands to the same device. Override it if you need to. Valid range is 1 to 600. A delay is a recommendation of Digital Loggers: Many loads draw more power when they are initially switched on. Sequencing prevents circuit overloads when loads devices are attached to a single circuit.

Default value:

2

릴레이는 switch.fantasticrelaydevice_individualrelayname 형식으로 제공됩니다.